Highly Sensitive Toxic Gas Detector FP-300 / FP-300P / FP-330

      Technical Data & Features

      • PPB detection for many gases
      • Easily transportable
      • Panel mounting configuration available
      • Excellent selectivity and low interference from other gases

      Properties:

      Sampling method
      Suction type / Single type
      Principle of detection
      Chemical Tape Method
      Detection range
      Depends on target gas
      Type of alarm
      Gas alarm / fault alarm
      Display of alarm
      Lamp lighting / buzzer
      Explosion protected construction
      Non-explosion protection
      CE marking
      EMC / LVD / RoHs (AC specification only)
      Power source
      100 VAC to 240 VAC ± 10% 50/60 Hz (Desktop type)

      24 VDC ±10 % (Panel mounting type)
      Dimensions
      Approx. 164(W) x 198(H) x 263(D) mm (Desktop type) 

      Approx. 164(W) x 164(H) x 263(D) mm (Panel mounting type)
      Weight
      Approx 6.5kg (Desktop type)

      Approx 5.5kg (Panel mounting type)
      Operating temperature range
      5 to 35°C (no sudden changes)
      Operating humidity range
      30 to 80 %RH (no condensation)
      Target gas (FP-300P)

      Phosgene - COCL2
      0.2-4 ppm
      0-300 ppb

      Target gas (FP-330)

      Formaldehyde - HCHO
      0-0.5 ppm
      0-1 ppm
      0-5 ppm

      Target gas (FP-300)

      HCL, HBr, HCL, HF, CLF3, NH3, TEMAH TMA, CL2, CL2, RuO4, AsH3, H2S, H2S, PH3, H2Se, AsH3, SiH4, B2H6, PH3, PH3, AsH3, Si2H6, TBAs, H2S, H2S, H2S, CL2, CL2, GeH4, GeH4, PH3, COCL2, COCL2

      Documents to download

      Download instructions
      Download catalogs
      Download certificates

      Similar products

      Fixed Gas Detector SD-2500
      For high-boiling point solvents
      Fixed Gas Detector OX-600
      Oxygen Deficiency Monitor
      Fixed Gas Detector SD-3RI
      For combustible / toxic gases