Portable Gas Detector 04 Series: CO-04 (C-)

      Technical Data & Features

      • Single-component portable gas detector with a long
continuous operating time
      • Durable R sensor with advanced functions
      • 3-year sensor warranty

      Properties:

      Sampling method
      Diffusion type / Single type
      Principle of detection
      Potentiostatic Electrolysis Method
      Detection range
      0 to 500 ppm (Display range 0 to 300 ppm / 300 to 2,000 ppm)
      Alarm setpoints
      1st 25 ppm, 2nd 50 ppm, 3rd 1200 ppm, TWA 25 ppm, STEL 200 ppm, OVER 2,000 ppm
      Display of alarm
      Flashing lamp / intermittent buzzer sounding / gas concentration display blinking / vibration
      Explosion protected construction
      Intrinsic safety
      Explosion proof class
      IECEx: Ex ia II C T4 Ga (AAA alkaline), Ex ia II C T3 Ga (Ni-MH)

      ATEX: II 1G Ex ia II C T4 Ga (AAA alkaline), II 1G Ex ia II C T3 Ga (Ni-MH)
      Ingress protection rating
      Equivalent to IP66/67
      Approvals
      Japan Ex, ATEX, IECEx, China Ex
      CE marking
      EMC / ATEX / RoHS
      Power source
      AAA alkaline or Ni-MH (eneloop) batteries (x2)
      Continuous operation
      Approx. 6,200 hours (AAA alkaline)

      Approx. 4,200 hours (Ni-MH)
      Dimensions
      Approx. 54 (W) x 67 (H) x 24 (D) mm (excluding projections)
      Weight
      Approx. 93g
      Operating temperature range
      -40°C to +60°C (no sudden changes)
(Approx. 15-minute temporary use environment: -20°C to +50°C [no sudden changes])
      Operating humidity range
      0 to 95 %RH (no condensation)
(Approx. 15-minute temporary use environment: 10 to 90 %RH [no condensation])
      Operating pressure range
      80 to 120 kPa (80 to 110 kPa for explosion-proof range)
      Target gases
      CO