Portable Gas Detector NC-1000
Technical Data & Features
- Direct reading of the concentration values of 25 types of combustible gases
- Easy operation by changing the gas name display with one button
- Long distance measuring possible with the pump booster function
- Various combustible gases can be measured in ppm
Properties:
- Sampling method
- Suction type / Single type
- Principle of detection
- New Ceramic Catalytic Method
- Detection range
- 0 to 10,000 ppm (automatic range switching); Low : 0 to 1,000 ppm; High : 0 to 10,000 ppm
- Alarm setpoints
- 1st 250 ppm / 2nd 500 ppm
- Display of alarm
- Intermittent buzzer sound / blinking alarm lamp (red) and blinking gas / concentration display
- Explosion protected construction
- Intrinsic safety
- Explosion proof class
- IECEx : Ex ia IIC T4 Ga
ATEX : II1G Ex ia IIC T4 Ga - Ingress protection rating
- Equivalent to IP67
- Approvals
- Japan Ex, ATEX, IECEx
- CE marking
- EMC / ATEX / RoHS
- Power source
- AA alkaline battery (4x)
- Continuous operation
- Approx. 15hours (new dry batteries, without alarms or lighting, at 25ºC) (CH4 spec.)
Approx. 20hours (new dry batteries, without alarms or lighting, at 25ºC) (HC spec.) - Dimensions
- Approx. 80 (W) x 124 (H) x 36 (D) mm (excluding projections)
- Weight
- Approx. 260 g (without batteries)
- Operating temperature range
- -20 to +50℃ (no sudden changes)
- Operating humidity range
- 0 to 95 %RH (no condensation)
- Target gases
- C2H2, C2H4, C2H5OH, C2H6, C3H6, C3H6O, C3H8, C4H6, C5H10, C6H12O2, C6H6, C7H8, C8H10, C8H8, CH3OH, CH4, DME, EO, EtAc, H2, i-C4H10, IPA, ISOPARH, MEK, MIBK, MMA, n-C4H10, n-C6H14, n-C7H16, THF, VAc