Fixed Gas Detector / Gas Detector with Signal Converter
SD-3 Series: SD-3NC

      Technical Data & Features

      • Next generation, high-performance F Sensor installed, greatly improving both functionality and performance
      • Compliant with different global standards
      • Wide range of output options
      • Rugged housing construction for use in harsh environments
      • Wide range of types to suit a variety of uses and installation environments

      Model list

      • SD-3NC (Diffusion type)
      • SD-3DNC (Suction type)
      • SD-3SC+GD-3NC (Remote type)

      Properties:

      Sampling method
      Suction type / Single type, Diffusion type / Single type
      Principle of detection
      New Ceramic Catalytic Method
      Explosion protected construction
      Flameproof enclosures
      Explosion proof class
      IECE: Ex db II C T5/T4 Gb

      ATEX: II 2G Ex db II C T5/T4 Gb
      Ingress protection rating
      Equivalent to IP66/67
      Approvals
      Japan Ex, ATEX, IECEx, China Ex, SIL
      CE marking
      EMC / LVD / ATEX / RoHS
      Power source
      24 VDC (18 to 30 VDC)
      Dimensions
      Approx. 171(W) x 277(H) x127(D) mm (SD-3NC)
      Approx. 171(W) x 289(H) x 127(D) mm (SD-3DNC) (excluding projections)
      Weight
      Approx. 6.7kg (SD-3NC)
      Approx. 7.0kg (SD-3DNC)
      Operating temperature range
      -20°C to +70°C [Japan Ex] (no sudden changes)
      -40°C to +70°C [ATEX/IECEx] (no sudden changes)
      Operating humidity range
      0 to 95 %RH (no condensation)
      Target gases
      C2H2, C2H4, C2H5OH, C2H6, C3H6, C3H6O, C3H8, C4H6, C7H8, C8H18, CH3OH, CH4, DMAC, H2, i-C4H10, i-C4H8, IPA, n-C6H14, VCM

      Similar products

      SD-1EC, SD-1DEC
      Fixed Gas Detector / Smart Transmitter
SD-1 Series: SD-1EC, SD-1DEC
      SD-3GH
      Fixed Gas Detector / Gas Detector with Signal Converter
SD-3 Series: SD-3GH
      PLU-70
      Fixed Pyrolyzer Unit GD-70D Series: PLU-70