Portable Gas Detector 04 Series: SC-04
Technical Data & Features
- Single-component portable gas detector with a long continuous operating time
- Durable R sensor with advanced functions
- Up to 3-year sensor warranty, depending on sensor
Properties:
- Sampling method
- Diffusion type
- Principle of detection
- Potentiostatic Electrolysis Method
- Detection range
- SO2: 0.00 to 20.00 ppm (Display range 0.00 to 100.00 ppm)
NO2: 0.00 to 20.00 ppm
HCN: 0.0 to 30.0 ppm
PH3: 0.00 to 20.00 ppm
NH3: 0.0 to 300.0 ppm (Display range 0.0 to 400.0 ppm) Cl2: 0.00 to 10.00 ppm (Display range 0.00 to 20.00 ppm) - Alarm setpoints
- Depends on target gas
- Display of alarm
- Flashing lamp / intermittent buzzer sounding / gas concentration display blinking / vibration
- Explosion protected construction
- Intrinsic safety
- Explosion proof class
- IECEx: Ex ia II C T4 Ga (AAA alkaline), Ex ia II C T3 Ga (Ni-MH)
ATEX: II 1G Ex ia II C T4 Ga (AAA alkaline), II 1G Ex ia II C T3 Ga (Ni-MH) - Ingress protection rating
- Equivalent to IP66/67
- Approvals
- Japan Ex, ATEX, IECEx, China Ex
- CE marking
- EMC / ATEX / RoHS
- Power source
- AAA alkaline or Ni-MH (eneloop) batteries (x2)
- Continuous operation
- Approx. 3,000 hours (AAA alkaline)
Approx. 2,000 hours (Ni-MH) - Dimensions
- Approx. 54 (W) x 67 (H) x 24 (D) mm (excluding projections)
- Weight
- Approx. 93g
- Operating temperature range
- SO2, NO2, PH3, Cl2: -40°C to +60°C (no sudden changes)
HCN: -20°C to +60°C (no sudden changes)
NH3: -30°C to +50°C (no sudden changes)
(Approx. 15-minute temporary use environment: -20°C to +50°C [no sudden changes]) - Operating humidity range
- 0 to 95 %RH (no condensation) (Approx. 15-minute temporary use environment: 10 to 90 %RH [no condensation])
- Operating pressure range
- 80 to 120 kPa (80 to 110 kPa for explosion-proof range)
- Target gases
- Cl2, HCN, NH3, NO2, PH3, SO2