Portable Toxic Gas Detector SC-8000

      Technical Data & Features

      • Extensive gas range
      • Two easy-to-understand displays: digital and analogue
      • Buzzer volume control function
      • Alterable target gases

      Properties:

      Sampling method
      Suction type / Single type
      Principle of detection
      Potentiostatic Electrolysis Method
      Detection range
      Depends on target gas
      Display of alarm
      Lamp blinking / buzzer / gas concentration display blinking
      Explosion protected construction
      Intrinsic safety
      Explosion proof class
      IECEx: Ex ia II C T4 Ga

      ATEX: II 1G Ex ia II C T4 Ga
      Ingress protection rating
      Equivalent to IP67
      Approvals
      Japan Ex, ATEX, IECEx
      CE marking
      EMC / ATEX / RoHS
      Power source
      Dry battery unit (AA alkaline battery (x3)) or
Lithium-ion battery unit
      Continuous operation
      Approx. 18 hours [Dry battery unit]
      Approx. 25 hours [Lithium-ion battery unit]
      Dimensions
      Approx. 154 (W) x 81 (H) x 154 (D) mm (excluding projections)
      Weight
      Approx. 1.0 kg [Dry battery unit]

      Approx. 1.1 kg [Lithium-ion battery unit]
      Operating temperature range
      -10°C to +40°C (no sudden changes)
      Operating humidity range
      30 to 70 %RH (no condensation)
      Target gases
      AsH3, B2H6, Br2, BTBAS, C2H4O2, C6H15N, CH3SiH3, CL2, CLF3, CO, DEA, DMA, EMA, F2, GeH4, H2O2, H2S, H2Se, HBr, HCL, HCN, HF, HI, HNO3, I2, MMtA, N2H4, N2O4, NH3, NO, NO2, O3, PF3, PH3, Si2H6, Si3H9N, SiH4, SO2, TMA